CMS-10R-DA/DC12-48V-Z1
- For use in 4G, 3G, 2G mobile networks
- Zone 1: Worldwide
- Inputs: 6 x digital / analogue (0-10 V) selectable
- Outputs: 4 x changeover contacts, 10 A @ 250 V AC each
- Contact type: Screw connection
CMS-10R-DA/DC12-48V messaging system
Remote control of outputs and status queries of inputs and outputs via SMS, pager, voice call, push/email notification, remote configuration via web browser, application available for Android/iOS devices, supported communication standards GSM (2G) / UMTS (3G) / LTE (4G), integrated eSIM, operating voltage: 10 ... 48 V DC, Inputs: 6 x digital/analogue combination, Outputs: 4 x changeover contact (10 A / 250 V AC), 50 mm antenna, Power consumption 1 W, Operating temperature range -25 ... 55 °C, IP40, 5 TE DIN, grey plastic housing
Remote control of outputs and status queries of inputs and outputs via SMS, pager, voice call, push/email notification, remote configuration via web browser, application available for Android/iOS devices, supported communication standards GSM (2G) / UMTS (3G) / LTE (4G), integrated eSIM, operating voltage: 10 ... 48 V DC, Inputs: 6 x digital/analogue combination, Outputs: 4 x changeover contact (10 A / 250 V AC), 50 mm antenna, Power consumption 1 W, Operating temperature range -25 ... 55 °C, IP40, 5 TE DIN, grey plastic housing
| Current type | DC |
|---|---|
| Nominal voltage | 12 V-48 V |
| Antenna connector type | SMA female |
|---|---|
| Antenna impedance | 50 Ω |
| Antenna jack torque (max) | 1 |
| Antenna return loss | > 10 dB |
| Communication Standards | E-GSM (2G), E-UTRA (3G), LTE (4G) |
| eSIM | Embedded |
| Frequency bands Z1 | E-GSM: B2, B3, B5, B8 | E-UTRA: B1, B2, B4, B5, B6, B8, B19 | LTE-FDD: B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19, B20, B25, B26, B28 | LTE-TDD: B38, B39, B40, B41 |
| Frequency bands Z2 | E-GSM: B3, B8 | E-UTRA: B1, B8 | LTE-FDD: B1, B3, B7, B8, B20, B28A |
| Network coverage | Weltweit |
| Classification | Manual Control (IEC 60730-1) |
|---|---|
| Operation | Type 1 (IEC 60730-1) |
| Software class | Class A (IEC 60730-1) |
| Housing material | PA |
|---|---|
| Ingress Protection | IP 40 |
| Mounting | DIN Rail (IEC 60715) and Panel mount |
| Operation Altitude | Max. 2 000 m / 6 562 ft over sea level (without derating) |
| Operation Position | any |
| Operation temperature | -25 … 70 °C / -13 ... 158 °F |
| Relative huminity, no condensation | 10 … 95 % |
| Storage temperature (no ice) | -40 … 85 °C / -40 ... 185 °F |
| Weight | 260 g |
| Logic level '0' digital inputs | < 4.0 V DC |
|---|---|
| Logic level '1' digital inputs | > 6.0 V DC |
| Maximal voltage digital inputs | 48 V DC |
| Measurement category | 2 |
| Nominal range analogue voltage inputs | 0 ... 10 V, Compliant with IEC 60381-2 |
| Number of analogue voltage / digital inputs | 6 |
| Resolution of analogue inputs | 12 |
| Sampling rate per channel | 10 |
| Voltage input impedance | 196 kΩ |
| Insulation rating between all ports | 2 kV / 1 min |
|---|---|
| Insulation type | Reinforced |
| Overvoltage category | II |
| Pollution degree | 2 |
| Rated impulse voltage | 2.5 kV / 1 min |
| Shock/vibration proof | IEC 61373 |
| Contact material | AgNi |
|---|---|
| Electrical endurance at rated load AC-1 (cycles) | > 30 000 |
| Maximum switching voltage | 400 V AC |
| Number of relay outputs | 4 |
| Rated current AC-1 | 10 A |
| Rated load AC-1 | 3 |
| Rated voltage | 250 V AC |
| Recommended minimum load | 10 mA, 12 V |
| Type of terminal | CO |
| Additional power consumption per output | 0.45 W |
|---|---|
| Maximum power consumption | 6 W |
| Nominal operating voltage | 10 ... 48 V DC |
| Nominal voltage | 10 ... 48 VDC |
| Operating voltage range | 8.4 ... 60 V DC |
| Typical power consumption (without any output set) | < 1 W |
| Approvals | CE,UKCA |
|---|---|
| Standards | IEC/EN/BSI/UL/CSA 60730,CISPR 32 / EN 55032,IEC 61000-6-2/-3,ETSI EN 301511,ETSI EN 301908-1/-2/-13,IEC 60381-1/-2,IEC 62368-1,IEC/EN/BSI/AS/NZS/SANS 62368 |
| Conductor cross section control / main circuit | 4 mm2 / AWG12 (Wire), 2.5 mm2 / AWG14 (Stranded), 1.00 mm2 / AWG17 (Ferrule). Use copper conductors only. |
|---|---|
| Contact type control / main circuit | Screw connection |
| Dual sleeve control / main circuit | 1 |
| Max. wire count control / main circuit | 2 |
| Nominal screw torque control / main circuit | 0.5 Nm / 4.425 lbf in |
| Screwdrive control / main circuit | PZ2 |
| Stripping Length control / main circuit | 8 mm / 0.31" |
Approvals
Release Notes "CMS-10R-DA/DC12-48V-Z1"
CMS-10R IoT Portal Version 1.9.0
CMS-10R Firmware Version 1.3.1
CMS-10R Firmware Version 1.3.0 und IoT-Portal Version 1.8.0
CMS-10R IoT Portal Version 1.7.0
CMS-10R IoT Portal Version 1.6.0
CMS-10R Firmware Version 1.2.0 und IoT-Portal Version 1.5.0
CMS-10R IoT Portal Version 1.4.0
CMS-10R IoT Portal Version 1.3.0
CMS-10R IoT Portal Version 1.2.0
CMS-10R Firmware Version 1.1.1
CMS-10R IoT Portal und Firmware Version 1.1.0
CMS-10R Firmware Version 1.0.2 und IoT-Portal Version 1.0.6
CMS-10R IoT-Portal und Firmware-Version 1.0.0
CMS-10R System Information
CMS-10R Firmware Version 0.3.0
CMS-10R IoT Portal Version 0.3.0
CMS-10R Firmware Version 0.2.1
CMS10-R Firmware Version 0.2.0 und IoT-Portal Version 0.2.0
CMS-10R IoT Portal Version 2.0.0
CMS-10R IoT Portal Version 2.0.2
CMS-10R Firmware Version 1.3.1
CMS-10R Firmware Version 1.3.0 und IoT-Portal Version 1.8.0
CMS-10R IoT Portal Version 1.7.0
CMS-10R IoT Portal Version 1.6.0
CMS-10R Firmware Version 1.2.0 und IoT-Portal Version 1.5.0
CMS-10R IoT Portal Version 1.4.0
CMS-10R IoT Portal Version 1.3.0
CMS-10R IoT Portal Version 1.2.0
CMS-10R Firmware Version 1.1.1
CMS-10R IoT Portal und Firmware Version 1.1.0
CMS-10R Firmware Version 1.0.2 und IoT-Portal Version 1.0.6
CMS-10R IoT-Portal und Firmware-Version 1.0.0
CMS-10R System Information
CMS-10R Firmware Version 0.3.0
CMS-10R IoT Portal Version 0.3.0
CMS-10R Firmware Version 0.2.1
CMS10-R Firmware Version 0.2.0 und IoT-Portal Version 0.2.0
CMS-10R IoT Portal Version 2.0.0
CMS-10R IoT Portal Version 2.0.2
Documents "CMS-10R-DA/DC12-48V-Z1"
Tools "CMS-10R-DA/DC12-48V-Z1"
Error messages
Mobile payment with the phone not allowed
This message appears when the country of origin of the credit card does not match the country where it is being used. For legal reasons, the European Union requires a double location check. The system reviews the country of origin of the credit card and the location of the IP address. Both must match. If the device is in Switzerland but the card is issued in another country, the payment is rejected for legal reasons. A possible alternative is to use a Swiss credit card within Switzerland.