SSU33L/AC400V 50HZ

The SSU33L 3-phase mains monitoring device is an easy-to-use monitoring relay for the 230V/400V 3-phase mains.
This device is available in two versions. One is the SSU33L/AC230V for a network with neutral conductor, and the other is the SSU33L/AC400V for a network without neutral conductor.
The devices monitor the conductor voltages, frequency, symmetry and direction of rotation. The monitoring criteria are linked internally and their sensitivity is set by the operator using a rotary knob.
A second rotary knob is used to set the alarm delay.

Current type AC (50 Hz)
Nominal voltage 400 V

Housing material PC
Ingress Protection IP 20
Operation temperature -25 … 60 °C
Storage temperature (no ice) -40 … 85 °C
Weight 300 g

Overvoltage category III
Pollution degree 2
Rated test voltage measuring / measuring circuit 2 kV rms / 1 min
Rated test voltage measuring circuit / main circuit 2 kV rms / 1 min
Rated test voltage open contact 1 kV rms / 1 min

Contact materials AgNi
Mechanical endurance (cycles) 30 000 000
Minimum load 10 mA, 5 V
Number of contacts 1 CO
Rated current 6 A
Rated load AC-1 1500 VA
Rated voltage 250 V AC

AC voltage measurement range L-N / L-L - / 280 … 480 V
Alarm delay 0.2 … 5 s
Frequency difference setting range L-N / L-L 3 … 15 Hz
Measured parameters U, ΔPhi, Δf
Monitoring functions Under, over, phase failure, phase sequence
Number of voltage measurement inputs 3 (L1 / L2 / L3)
Overvoltage setting range ≥ 480 V
Phase angle difference setting range L-N / L-L 3 … 15°
Rated AC voltage L-N / L-L - / 400 V
Rated base frequency 50 Hz
Undervoltage setting range ≤ 280 V
Voltage difference setting range L-N / L-L 20 … 100 V / 35 … 173 V

Frequency range 50 Hz
Nominal voltage 400 V AC
Operating voltage range 280 … 470 V
Power consumption AC / DC 3 VA / -

Approvals UKCA,CE,EAC,cURus
Standards IEC/EN 60947
3D-models "SSU33L/AC400V 50HZ"

Current type AC (50 Hz)
Nominal voltage 400 V

Housing material PC
Ingress Protection IP 20
Operation temperature -25 … 60 °C
Storage temperature (no ice) -40 … 85 °C
Weight 300 g

Overvoltage category III
Pollution degree 2
Rated test voltage measuring / measuring circuit 2 kV rms / 1 min
Rated test voltage measuring circuit / main circuit 2 kV rms / 1 min
Rated test voltage open contact 1 kV rms / 1 min

Contact materials AgNi
Mechanical endurance (cycles) 30 000 000
Minimum load 10 mA, 5 V
Number of contacts 1 CO
Rated current 6 A
Rated load AC-1 1500 VA
Rated voltage 250 V AC

AC voltage measurement range L-N / L-L - / 280 … 480 V
Alarm delay 0.2 … 5 s
Frequency difference setting range L-N / L-L 3 … 15 Hz
Measured parameters U, ΔPhi, Δf
Monitoring functions Under, over, phase failure, phase sequence
Number of voltage measurement inputs 3 (L1 / L2 / L3)
Overvoltage setting range ≥ 480 V
Phase angle difference setting range L-N / L-L 3 … 15°
Rated AC voltage L-N / L-L - / 400 V
Rated base frequency 50 Hz
Undervoltage setting range ≤ 280 V
Voltage difference setting range L-N / L-L 20 … 100 V / 35 … 173 V

Frequency range 50 Hz
Nominal voltage 400 V AC
Operating voltage range 280 … 470 V
Power consumption AC / DC 3 VA / -

Approvals UKCA,CE,EAC,cURus
Standards IEC/EN 60947
Approvals
3D-models "SSU33L/AC400V 50HZ"
Skip product gallery

Accessories

S3-M
S3-M
- 10 A @ 250 V
- Module compartment for time or monitoring modules
- Screw terminal

HF-24
HF-24
- Compatible with: SSU31, SSU33L, TSR19

FS-23
FS-23
- Compatible with: SSU31, SSU33L, TSR19

FZ-23
FZ-23
- Compatible with: SSU31, SSU33L, TSR19