SSU31/AC400V
The SSU31 is used to monitor the phase sequence and detect undervoltage and phase failure in three-phase networks.
The monitoring function is used to ensure the drive direction of pumps and conveyor systems, particularly in mobile systems with plug connections. Switching off at a defined undervoltage and phase failure protects against malfunctions and damage due to overheating.
The monitoring function is used to ensure the drive direction of pumps and conveyor systems, particularly in mobile systems with plug connections. Switching off at a defined undervoltage and phase failure protects against malfunctions and damage due to overheating.
| Current type | AC (50 Hz) |
|---|---|
| Nominal voltage | 400 V |
| Housing material | PC |
|---|---|
| Ingress Protection | IP 20 |
| Operation temperature | -25 … 60 °C |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 300 g |
| Overvoltage category | III |
|---|---|
| Pollution degree | 2 |
| Rated test voltage measuring / measuring circuit | 2 kV rms / 1 min |
| Rated test voltage measuring circuit / main circuit | 2 kV rms / 1 min |
| Rated test voltage open contact | 1 kV rms / 1 min |
| Contact materials | AgNi |
|---|---|
| Mechanical endurance (cycles) | 30 000 000 |
| Minimum load | 10 mA, 5 V |
| Number of contacts | 1 CO |
| Rated current | 6 A |
| Rated load AC-1 | 1500 VA |
| Rated voltage | 250 V AC |
| AC voltage measurement range L-N / L-L | 320 … 400 V |
|---|---|
| Measured parameters | U |
| Monitoring functions | Under, phase failure, phase sequence |
| Number of voltage measurement inputs | 3 (L1 / L2 / L3) |
| Rated AC voltage L-N / L-L | - / 400 V |
| Rated base frequency | 45 … 65 Hz |
| Undervoltage setting range | ≤ 320 V |
| Frequency range | 45 … 65 Hz |
|---|---|
| Nominal voltage | 400 V AC |
| Operating voltage range | 360 … 470 V |
| Power consumption AC / DC | 10 VA / 1.5 W |
| Approvals | UKCA,CE,EAC,cURus |
|---|---|
| Standards | IEC/EN 60947 |
3D-models "SSU31/AC400V"
| Current type | AC (50 Hz) |
|---|---|
| Nominal voltage | 400 V |
| Housing material | PC |
|---|---|
| Ingress Protection | IP 20 |
| Operation temperature | -25 … 60 °C |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 300 g |
| Overvoltage category | III |
|---|---|
| Pollution degree | 2 |
| Rated test voltage measuring / measuring circuit | 2 kV rms / 1 min |
| Rated test voltage measuring circuit / main circuit | 2 kV rms / 1 min |
| Rated test voltage open contact | 1 kV rms / 1 min |
| Contact materials | AgNi |
|---|---|
| Mechanical endurance (cycles) | 30 000 000 |
| Minimum load | 10 mA, 5 V |
| Number of contacts | 1 CO |
| Rated current | 6 A |
| Rated load AC-1 | 1500 VA |
| Rated voltage | 250 V AC |
| AC voltage measurement range L-N / L-L | 320 … 400 V |
|---|---|
| Measured parameters | U |
| Monitoring functions | Under, phase failure, phase sequence |
| Number of voltage measurement inputs | 3 (L1 / L2 / L3) |
| Rated AC voltage L-N / L-L | - / 400 V |
| Rated base frequency | 45 … 65 Hz |
| Undervoltage setting range | ≤ 320 V |
| Frequency range | 45 … 65 Hz |
|---|---|
| Nominal voltage | 400 V AC |
| Operating voltage range | 360 … 470 V |
| Power consumption AC / DC | 10 VA / 1.5 W |
| Approvals | UKCA,CE,EAC,cURus |
|---|---|
| Standards | IEC/EN 60947 |