MRM11R/UC110-240V

- 1 Changeover contact
- Contact material AgNi
- Measuring range 0.1-480 V AC / 0.1-690 V DC / 0.1-5 A
- For installation in electrical distributor
- Monitoring: U, I, f, P, S, Cos ϕ
ELDAS®: 7630005146811

Current type AC / DC (50 Hz)
Nominal voltage 110 V-240 V

Conductor cross section control / main circuit 2.5 mm2
Housing material PA
Ingress Protection IP 20
Nominal screw torque control / main circuit 0.6
Operation temperature -40 … 70°C
Storage temperature (no ice) -40 … 85 °C
Weight 107 g

Overvoltage category III
Pollution degree 2
Rated test voltage main circuit / power supply 2 kV rms / 1 min
Rated test voltage measuring / measuring circuit 1.5 kV rms / 1 min
Rated test voltage measuring circuit / main circuit 2 kV rms / 1 min
Rated test voltage measuring circuit / power supply 2 kV rms / 1 min
Rated test voltage open contact 1.5 kV rms / 1 min

Contact materials AgNi
Mechanical endurance (cycles) 30 000 000
Minimum load 10 mA, 10 V
Number of contacts 1 CO
Rated current 6 A
Rated load AC-1 1250 VA
Rated voltage 250 V AC

AC voltage measurement range L-N / L-L 0.1 … 480 V
Alarm delay 0.5 … 999.9 s
Alarm reset delay 0.5 … 999.9 s
DC voltage measurement range U+ / U- +0.1 … +690 V, -0.1 … -690 V
Measured parameters U, I, P, S, f, Cosϕ
Measurement current range 0.1 … 5 A
Min. setting step, resolution 0.1 V / 0.1 A / 1 W / 1 VA / 1 Hz / 0.05
Monitoring functions Under, over, inside, outside
Number of current measurement inputs 1
Number of voltage measurement inputs 1
Overcurrent threshold Ith setting range 0.1 … 6 A
Overvoltage setting range +0.1 … +700 V, -0.1 … -700 V
Rated AC voltage L-N / L-L 230 V / -
Rated base frequency 15 … 150 Hz
Rated DC voltage U+ / U- 300
Rated measurement current 5
Undercurrent setting range 0.1 … 6 A
Undervoltage setting range +0.1 … +700 V, -0.1 … -700 V

Frequency range 16 … 63 Hz
Nominal voltage 110 … 240 V AC / DC
Operating voltage range 77 … 250 V
Power consumption AC / DC 2.6 VA / 1.5 W

Approvals UKCA,CE,cULus,EAC,Railway
Railway EN 50155,EN 45545-2
Standards EN 60947-1,EN 60730-1,EN 61000-6-3,EN 61000-6-2
Approvals
3D-models "MRM11R/UC110-240V"
Documents "MRM11R/UC110-240V"
Monitoring Devices

Voltage, current, frequency, active power, apparent power, cos Phi, Delta Phi (phase sequence)

The device data sheet and the package insert contain a description of the menu navigation, etc.

Press both arrow keys simultaneously to access the menu. When you enter the settings, you will be guided through the menu automatically.

To measure currents greater than 5A, current transformers are required that are specified for 5A on the secondary side. This allows high currents to be measured, but the scaling factor must then be adjusted in the settings.