Skip to main content Skip to search Skip to main navigation

CRINT-R31/DC24V

General data -40...85 °C
Main circuit 0
Technical approvals, conformities IEC/EN 61810

Inputs 0.7 UN … 1.25 UN
Input current ≤ 0.7 UN mA
Power consumption AC / DC 0.4 W
Max. Pick-up time ≥ 0.1 UN
TVS Diode failure mode -40...85 °C

Operation temperature -40...85 °C
Pick-up time ≤ 15 ms
Release time ≤ 8 ms
Storage temperature (no ice) -40...85 °C
Weight 12 g

Insulation resistance at 500 V ≥ 1 GΩ
Test voltage contact / coil ≥ 1 GΩ
Test voltage open contact 5 kV / 1 min
Test voltage all terminals / DIN rail 1 kV / 1min

Electrical endurance at rated load AC-1 (cycles) ≥ 50 000
Maximum contact load AC-1 16A / 250 V AC-1
Maximum contact load DC-1 16A / 24 V DC-1
Mechanical endurance (cycles) ≥ 10 000 000
Number of contacts 1 CO
Rated current 16 A
Rated load AC 4 000 VA

Approvals CE,EAC,UKCA,cURus
Standards IEC/EN 61810
Railway Bild