CRINT-C131R/DC24-110V
Koppelrelais Set bestehend aus Sockel mit Push-in Kontakten und AgSnO2 Relais
| Nominal voltage | 24 V-110 V |
|---|---|
| Current type | DC |
| Pick-up voltage | ≤ 16.8 V |
|---|---|
| Operating voltage range | 16.8 ... 154 V |
| Power consumption AC / DC | – / 0.4 W |
| Release voltage | ≥ 7.2 V |
| Variant | Push-in |
|---|
| - Multi wire (crimped) | 0.34 mm2 / AWG 22 … 1.5 mm2 / AWG 16 |
|---|---|
| - Multi wire (un-crimped) | 0.34 mm2 / AWG 22 … 2.5 mm2 / AWG 14 |
| - Single wire | 0.34 mm2 / AWG 22 … 2.5 mm2 / AWG 14 |
| Conductor cross section control / main circuit | Push-in terminal |
| Housing material | PA |
| Ingress Protection | IP 20 |
| Mounting | TH35 (EN 60715) |
| Operation temperature | -40 … 70 °C |
| Pick-up time | ≤ 20 ms |
| Release time | ≤ 25 ms |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 30 g |
| Overvoltage category | III |
|---|---|
| Pollution degree | 3 |
| Test voltage contact / coil | 4 kV / 1 min |
| Test voltage open contact | 1 kV / 1 min |
| Electrical endurance at rated load AC-1 (cycles) | ≥ 10 000 |
|---|---|
| Inrush current | 15 A, 2.5 ms |
| Maximum contact load AC-1 | 6 A / 250 V AC-1 |
| Maximum contact load DC-1 | 6 A / 30 V DC-1 |
| Mechanical endurance (cycles) | ≥ 1 000 000 |
| Rated current | 6 A |
| Rated load AC | 1 500 VA |
| Recommended minimum contact load | 100 mA / 5 V |
| Approvals | UKCA,CE,EAC,Railway |
|---|---|
| Railway | EN 50155,EN 45545-2 |
| Standards | IEC/EN 61810-1,EN 60664-1 |
Documents "CRINT-C131R/DC24-110V"
| Nominal voltage | 24 V-110 V |
|---|---|
| Current type | DC |
| Pick-up voltage | ≤ 16.8 V |
|---|---|
| Operating voltage range | 16.8 ... 154 V |
| Power consumption AC / DC | – / 0.4 W |
| Release voltage | ≥ 7.2 V |
| Variant | Push-in |
|---|
| - Multi wire (crimped) | 0.34 mm2 / AWG 22 … 1.5 mm2 / AWG 16 |
|---|---|
| - Multi wire (un-crimped) | 0.34 mm2 / AWG 22 … 2.5 mm2 / AWG 14 |
| - Single wire | 0.34 mm2 / AWG 22 … 2.5 mm2 / AWG 14 |
| Conductor cross section control / main circuit | Push-in terminal |
| Housing material | PA |
| Ingress Protection | IP 20 |
| Mounting | TH35 (EN 60715) |
| Operation temperature | -40 … 70 °C |
| Pick-up time | ≤ 20 ms |
| Release time | ≤ 25 ms |
| Storage temperature (no ice) | -40 … 85 °C |
| Weight | 30 g |
| Overvoltage category | III |
|---|---|
| Pollution degree | 3 |
| Test voltage contact / coil | 4 kV / 1 min |
| Test voltage open contact | 1 kV / 1 min |
| Electrical endurance at rated load AC-1 (cycles) | ≥ 10 000 |
|---|---|
| Inrush current | 15 A, 2.5 ms |
| Maximum contact load AC-1 | 6 A / 250 V AC-1 |
| Maximum contact load DC-1 | 6 A / 30 V DC-1 |
| Mechanical endurance (cycles) | ≥ 1 000 000 |
| Rated current | 6 A |
| Rated load AC | 1 500 VA |
| Recommended minimum contact load | 100 mA / 5 V |
| Approvals | UKCA,CE,EAC,Railway |
|---|---|
| Railway | EN 50155,EN 45545-2 |
| Standards | IEC/EN 61810-1,EN 60664-1 |
Approvals
Documents "CRINT-C131R/DC24-110V"