C55/UC110-240V
- 2 pole
- Changeover contacts
- Contact material AgNi
- 5 A @ 250 V AC / 5 A @ 25 V DC
- Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V
- Changeover contacts
- Contact material AgNi
- 5 A @ 250 V AC / 5 A @ 25 V DC
- Time functions: E, W, H, B, I, A, K, N, M, G, F, Q, U, V
ELDAS®:
528738202
Current type | AC / DC (50 Hz) |
---|---|
Nominal voltage | 110 V-240 V |
Current consumption on input control B1 AC / DC | 4.2 mA / 4.2 mA |
---|---|
Current consumption on supply A1-A2 AC / DC | 15 mA / 15 mA |
Frequency range | 0; 50 ... 400 Hz |
Nominal voltage | 110 ... 240 V AC / DC |
Operating voltage range | 88 … 265 V AC / DC |
Power consumption AC / DC | 2 VA / 2 W |
Threshold voltage on input control B1 AC / DC | 50 V / 50 V |
Housing material | PC |
---|---|
Ingress Protection | IP 20 |
Operation temperature | -25 … 60 °C |
Storage temperature (no ice) | -40 … 85 °C |
Weight | 80 g |
Overvoltage category | III |
---|---|
Pollution degree | 2 |
Rated test voltage control / main circuit | 2 kV rms / 1 min |
Rated test voltage main / main circuit | 2 kV rms / 1 min |
Rated test voltage open contact | 1 kV rms / 1 min |
Contact materials | AgNi |
---|---|
Inrush current | 10 A, 10 ms |
Mechanical endurance (cycles) | 5 000 000 |
Minimum load | 10 mA, 12 V |
Number of contacts | 2 CO |
Rated current | 5 A |
Rated load AC-1 | 1250 VA |
Rated voltage | 250 V |
Approvals | UKCA,CE,EAC |
---|---|
Standards | IEC/EN 61812-1 |
Timing range | 0.01 s … 60 d |
---|---|
Timing scale | digital |
Approvals



3D-models "C55/UC110-240V"